Alternator works. Had it checked. Main black wire to alternator is hot. Orange wire to alternator is hot with key on. Truck appears to be grounded. Its a 1970 Dodge sweptline. I converted it to electronic ignition. Edited 1 time(s). Last edit at 04/27/2009 11:02AM by garyo. 
avatar
Re: Charging system not working.
Posted by: JimmieD (66.81.18.---)
Posts: 1,090
Date: April 27, 2009 03:37PM

Hey, Gary, on the Mopar Electronic Ignition system both the ECU ignition control and Electronic Voltage Regulator must have their casing/box connected to clean, bare metal ground. Sometimes a jumper wire is even needed. Also must have an engine to chassis ground strap, clean bare metal connection. If components like regulator or control box are attached to inner fender panel you may have to run a grounding wire from fender panel to firewall, to get continuity to engine-to-firewall ground.



Edited 1 time(s). Last edit at 04/27/2009 03:39PM by JimmieD.

Navigate: Previous MessageNext Message
Options: ReplyQuote


Subject Views Written By Posted
Charging system not working. 1589 garyo 04/27/2009 10:36AM
Re: Charging system not working. 487 JimmieD 04/27/2009 03:37PM
Re: Charging system not working. 521 PwrWgnDrvr 04/27/2009 05:57PM
Re: Charging system not working. 620 garyo 04/27/2009 11:30PM
Re: Charging system not working. 463 PwrWgnDrvr 04/28/2009 11:19AM
Re: Charging system not working. 655 JimmieD 04/29/2009 09:40AM
Re: Charging system not working. 530 JimmieD 04/28/2009 06:54AM
Re: Charging system not working. 487 steve 04/28/2009 12:04PM


Array
Sorry, only registered users may post in this forum.
This forum powered by Phorum.