Sweptline Showcase
Quote
PwrWgnDrvr
Remove the green wire from the alt. Connect a jumper to that terminal on the alt and touch it BRIEFLY to ground while the eng is running. If the ammeter goes to full scale, the problem is the regulator. If the ammeter does not move, the alt is bad. Its that simple. Good luck
Subject | Views | Written By | Posted |
---|---|---|---|
Charging system not working. | 1568 | garyo | 04/27/2009 10:36AM |
Re: Charging system not working. | 482 | JimmieD | 04/27/2009 03:37PM |
Re: Charging system not working. | 515 | PwrWgnDrvr | 04/27/2009 05:57PM |
Re: Charging system not working. | 614 | garyo | 04/27/2009 11:30PM |
Re: Charging system not working. | 457 | PwrWgnDrvr | 04/28/2009 11:19AM |
Re: Charging system not working. | 648 | JimmieD | 04/29/2009 09:40AM |
Re: Charging system not working. | 525 | JimmieD | 04/28/2009 06:54AM |
Re: Charging system not working. | 480 | steve | 04/28/2009 12:04PM |